LIMITED ONE-YEAR WARRANTY
If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge.
This warranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse
in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with
instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, such as surface and/or
weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL
IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY
AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE
DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b) completing a warranty claim online at
www.intermatic.com. This warranty is made by: Intermatic Incorporated, Customer Service 7777 Winn Rd., Spring Grove, Illinois 60081-9698. For warranty service go to:
http://www.Intermatic.com or call 815-675-7000.
INTERMATIC INCORPORATED, 7777 Winn Road
SPRING GROVE, ILLINOIS 60081-9698
www.intermatic.com
Troubleshooting Guide
Observed Problem Possible Cause Solution
Timer is blank until a button is pushed and No power (fuse or circuit breaker blown), loose wiring Make sure fuse is not blown and circuit
display changes between ON and OFF when connection or no load / burned out bulbs. breaker is on.
pressing door, but light stays OFF or flickers. Replace fuse if necessary.
Timer does not switch but display is normal. Timer not in AUTO, AUTO RAND(om), or MAN(ual) mode. Press MODE to select the desired operating
mode.
Timer works manually but does not follow Timer not in AUTO or AUTO RAND(om) mode. Press MODE to select AUTO RAND.
scheduled program.
Timer will not enter the AUTO or AUTO RAND Time of day and/or switching times are not programmed. Make sure time of day and at least one scheduled
modes when MODE is pressed. activity are programmed. See Set an ON/OFF Program.
Timer switches at incorrect times or skips Programmed schedule(s) are incorrect. Review ALL 7 ON/OFF switching time pairs by
some switching times. repeatedly pushing NEXT ON/OFF while in PGM
mode and revise as necessary.
Timer is in AUTO RAND(om) mode (varies switching times Press MODE to select AUTO mode.
up to + 15 minutes).
When using a combination of Astronomic and There are conflicting Astronomic and specific switching time 1. Complete the steps under “Setting the
specific switching times, the timer switches at settings. Your timer automatically skips any conflicting ON Calendar”.
unexpected times or does not switch when EVENTS as summer approaches to prevent unwanted opera- 2. Temporarily change your timer’s calendar
expected. tion of lights. See the next column if you wish to identify and setting to June 21st.
remove conflicting settings. 3. Review the SUNUP and SNST times by pressing
NEXT/ON/OFF.
4. Make sure your specific ON or OFF time set-
tings will not interfere with these Astronomic
switching times.
5. Be sure to change the date when you are done.
Load state does not match programmed state The timer does not “catch up” to the programmed load state. After entering your schedule or the time, then
immediately after programming the time or Instead, the load will remain in its current state prior to enter- returning to the AUTO modes, push NEXT/ON/OFF
schedule. ing the PGM mode. The timer will then begin following the to change the load state if necessary.
scheduled program at the next contrary ON/OFF time.
Load only operates when the remote (3-way) Remote switch is wired incorrectly. Verify the wiring is installed correctly,
switch is in one position or timer ignores the including the jumper.
remote switch.
Timer ignores remote (3-way) switch even Excessive length of wire (greater than 100 feet) or buried Eliminate condition by replacing the buried cable
though it is wired correctly. wiring to the remote switch. or doing without the remote switch. Consult
factory for other options.
Remote switch is defective or worn out. Replace the remote switch.
Load turns off immediately after being turned on. Remote switch or timer wired incorrectly, excessive length If the problem persists with the timer’s red wire
of wire (greater than 100 feet) or buried wiring to remote disconnected or with a remote switch temporarily
switch, or defective timer. connected right at the timer, replace the defective
timer. Otherwise try the above remedies.