Basic Operation
Parameter Description
IO–6. Sync-
On, Not-
Invert
Parameter setting for pin 6.
Not-
Invert
Indicates whether to invert the input/output pulse or
level signal.
Invert: Yes
Not-Invert: No
Invert
Sync-On This default function means that pin 6 per-
forms bi-directional and synchronous con-
trol over the turn-on of [On/Off].
Input Pin 6 receives the level signal from the
outside.
Output Pin 6 sends the digital signal (1, 0, PWM)
to the outside.
True By default (Not-Invert), the out-
put digital signal is 1 (i.e. low lev-
el), and in the case of Invert, the
output is high level.
False By default (Not-Invert), the out-
put digital signal is 0 (i.e. high lev-
el), and in the case of Invert, the
output is low level.
PWM Digital signal of PWM.
PWM Freq Frequency
PWM Duty Duty cycle
How to Use
When pin 6 is set to default Sync-On function, pin 6 has bi-directional I/O func-
tion, which can receive pulse signal input from the external instrument and also
can output pulse signal to external instrument. The parameter requirements of
this pulse signal are as follows:
Copyright © Itech Electronic Co., Ltd.
155

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3900C Series and is the answer not in the manual?

ITech IT-M3900C Series Specifications

General IconGeneral
BrandITech
ModelIT-M3900C Series
CategoryPower Supply
LanguageEnglish

Related product manuals