EasyManuals Logo
Home>ITech>Power Supply>IT-M3900C Series

ITech IT-M3900C Series User Manual

ITech IT-M3900C Series
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #169 background imageLoading...
Page #169 background image
Basic Operation
Level rise slope 10us
Level fall slope 2us
Minimum time width
for low level keep
30us
The bi-direction I/O functions are introduced as below:
Press [On/Off] on the instrument’s front panel, the instrument’s output is
changed from On to Off. At this point, the pulse signal output from pin 7 can
be detected.
When the instrument’s [On/Off] is in Off state, input pulse signal to pin 7,
and it will not impact the [On/Off] state.
When the instrument’s [On/Off] is in On state, input pulse signal to pin 7,
and [On/Off] will be changed from On to Off.
Taking two instruments as an example, the operation is as below:
1. Referring to the figure below, connect pin 7 of two instruments to the exter-
nal oscilloscope.
2. Set pin 7’s function of two instruments to Not-Invert and Sync-Off.
3. Confirm that the [On/Off] of both instruments is in On state.
4. Press [On/Off] on the front panel of instrument A to turn off the output
function.
At this time, check the oscilloscope. The instrument A’s pin 7 outputs pulse
signal and the instrument B’s output function is synchronously turned off.
Copyright © Itech Electronic Co., Ltd.
158

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3900C Series and is the answer not in the manual?

ITech IT-M3900C Series Specifications

General IconGeneral
BrandITech
ModelIT-M3900C Series
CategoryPower Supply
LanguageEnglish

Related product manuals