Technical Specification
Parameter IT-M3901C-10-170
Rise Time( no load ) Voltage
≤50ms
Rise Time( full load
)
Voltage
≤100ms
Fall Time( no load ) Voltage
≤50ms
Fall Time( full load ) Voltage
≤100ms
Transient Response
Time
Voltage
≤10ms
Line Regulation
Voltage
≤0.05% + 0.05%FS
Current ≤0.05% + 0.05%FS
Load Regulation
Voltage
≤0.002%*I + 0.05%FS
Current ≤0.05% + 0.05%FS
Output protection
OCP -125A or 175A
OVP 10.5V
Overpower
protection
-1224W or 1734W
Remote Sense
Compensation
Voltage
≤2V
External analog
optional
current program
External programming voltage -10V to 10V corre-
sponds to current -170A to 170A (effective range
-120A to 170A)
current monitor
Current -170A to 170A corresponds to external
monitoring voltage -10V to 10V (effective range
-120A to 170A)
voltage program
External programming voltage 0 to 10V Corre-
sponding voltage 0 to 10V
voltage monitor
Voltage 0 to 10V corresponds to external monitor-
ing voltage 0 to 10V
Other parameters:
AC Input
Voltage
3 phase: 110V520V
Single phase: 85V300V
Frequency
50Hz/60Hz
Max. apparent
power
1.85kVA
Max. input current
12.5Aac1
Max. efficiency
92%
Copyright © Itech Electronic Co., Ltd.
173

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3900C Series and is the answer not in the manual?

ITech IT-M3900C Series Specifications

General IconGeneral
BrandITech
ModelIT-M3900C Series
CategoryPower Supply
LanguageEnglish

Related product manuals