Basic Operation
Current Limit Display the maximum current limit.
Run Time Display the power-on time.
Boot Update Info Boot update information.
5.14 Restored to Factory Setting (System Reset)
This menu item is used to restore some parameter settings to factory setting
values.
The procedures to set the menu item are as follows.
1. Press the composite keys [Shift]+[P-set] (System) on the front panel to en-
ter the system menu.
2. Turn the knob to select the System Reset and press [Enter].
3. Press the Left / Right key or turn the knob to adjust the value of this
parameter.
• No: Default value, indicates the instrument cancels this menu setting.
• Yes: Indicates the instrument restores the factory default settings.
4. After the parameter settings are complete, press [Enter].
The parameters affected by System Reset and the parameter values after
reset are shown in the following table.
Table 5–2 Initial value of the parameter
Category
Parameter Initial Value
Main
interface
Voltage setting: Vset 0.002V(10V models)
0.2V(Other models)
Current setting: Iset One percent of the rated
current of the instrument
Upper limit of voltage: Vlim Upper limit value:
0.002V(10V models)
Upper limit value: 0.2V
(Other models)
Upper limit of current: Ilim One percent of the rated
current of the instrument
Upper limit of power: Plim Rated power value of
the instrument