Technical Specification
Storage
Temperature
-10℃~70
IP IP20
Isolation DC to GND 300Vdc
Isolation AC to GND 3500Vdc
Cooling
Air
Dimension
D*W*H
744.22mm*459mm*56.81mm
Weight( net) 10kg
*1: The ripple is got under three-phase AC input.
*2: At low voltage input, the set power will decrease. For more information,
please contact ITECH.
6.1.6 IT-M3904D-32-160
Parameter IT-M3904D-32-160
Rated value
Voltage
032V
Current 0A160A
Power 0W4000W
Resistance in series
CV priority
00.2Ω
Setup Resolution
Voltage
0.001V
Current 0.01A
Power 1W
Resistance in series
CV priority
0.001Ω
Read Back
Resolution
Voltage
0.001V
Current 0.01A
Power 1W
Setup Accuracy
Voltage
≤0.03% + 0.03%FS
Current ≤0.1% + 0.1%FS
Power ≤0.5% + 0.5%FS
Resistance in series
CV priority
≤1%FS