Technical Specification
Parameter IT-M3904D-800-16
Current ≤0.03% + 0.03%FS
Load Regulation
Voltage
≤0.01% + 0.01%FS
Current ≤0.05% + 0.05%FS
Output protection
OCP 16.8A
OVP 808V
Overpower
protection
4080W
Remote Sense
Compensation
Voltage
≤8V
External analog
optional
current program
External programming voltage 0V to 10V corre-
sponds to current 0A to 16A
current monitor
Current 0A to 16A corresponds to external monitor-
ing voltage 0V to 10V
voltage program
External programming voltage 0 to 800V Corre-
sponding voltage 0 to 10V
voltage monitor
Voltage 0 to 800V corresponds to external monitor-
ing voltage 0 to 10V
Other parameters:
AC Input
*2
Grid voltage range
3phase 200V480V
Single phase 100V240V
Frequency
50/60Hz
Max. apparent
power
4.5kVA
Max. input current
12.5Aac
Max. efficiency
94.5%
Power Factor 0.99
DC component
≤0.2A
Current harmonics ≤3%
Standard Interface
Standard: USB/LAN/CAN/IO
Optional: GPIB/Analog&RS232
Command Re-
sponse Time
0.1ms
Parallel Number ≤16
Working
Temperature
040
Copyright © Itech Electronic Co., Ltd.
164

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT-M3900D Series and is the answer not in the manual?

ITech IT-M3900D Series Specifications

General IconGeneral
BrandITech
ModelIT-M3900D Series
CategoryPower Supply
LanguageEnglish

Related product manuals