SCPI Command Description
Copyright© Itech Electronics Co., Ltd. 12
Chapter3 SCPI Command Description
STATus:QUEStionable[:EVENt]?
This command can be used to read the value in query event register.The power
supply will return a decimal number corresponding to the binary weighted sum
of each unit digit of register. These digits will be latched. After executing this
command, the query event register will be cleared.
Query syntax
STATus:QUEStionable[:EVENt]?
Arguments
None
Returns
<NR1>
Related Command
STATus:QUEStionable:ENABle
STATus:QUEStionable:CONDition?
This command is used to read the value of query condition register and
gets the status of power supply.
Query syntax
STATus:QUEStionable:CONDition?
Arguments
None
Returns
<NR1>
STATus:QUEStionable:ENABle
This command edits the enable register value of query event. In query, the
power supply will return a decimal number representing the binary weighted
sum of the enable register.
Command syntax
STATus:QUEStionable:ENABle <NRf>
Arguments
<.NR1> 065535

Table of Contents

Other manuals for ITech IT6522D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6522D and is the answer not in the manual?

ITech IT6522D Specifications

General IconGeneral
BrandITech
ModelIT6522D
CategoryPower Supply
LanguageEnglish

Related product manuals