EasyManuals Logo
Home>ITech>Power Supply>IT6532C

ITech IT6532C Manual

ITech IT6532C
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
Output Commands
Copyright© Itech Electronics Co., Ltd. 43
Command syntax
[SOURce:]EXTern[:STATe] <bool>
Arguments
ON|OFF|1|0
Reset Value
0
Example
EXT 1
Query syntax
[SOURce:]EXTern[:STATe]?
Returns
0|1
[SOURce:]EXTern:MONitor:RANGe
This command is used to set output range of external monitor.
Command syntax
[SOURce:]EXTern:MONitor:RANGe <10V|5V>
Arguments
10V|5V
Reset Value
10V
Example
EXT:MON:RANG 5V
Query syntax
[SOURce:]EXTern:MONitor:RANGe?
Returns
10V|5V
[SOURce:]EXTern:PROGram:MODE
This command is used to set external program mode.
Command syntax
[SOURce:]EXTern:PROGram:MODE <VOLTage| RESistance>

Table of Contents