LOAD:POWer:PROTection[:LEVel]
This command is used to set power value of load OPP.
Command syntax
LOAD:POWer:PROTection[:LEVel] <MINimum|MAXimum|DEFault|NRf>
Arguments
MINimum|MAXimum|DEFault|NRf
Unit
W
Reset Value
MAXimum
Example
LOAD:POW:PROT MAX
Query syntax
LOAD:POWer:PROTection[:LEVel]? [MINimum|MAXimum|DEFault]
Returns
NRf
LOAD:POWer:PROTection:DELay
This command is used to set delay time for load OPP.
Command syntax
LOAD:POWer:PROTection:DELay <MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf
Unit
S
Reset Value
0.5
Example
LOAD:POW:PROT:DEL 0.04