Load Commands
Copyright © Itech Electronic Co., Ltd. 21
Reset value:
CURRent
Query Syntax:
[SOURce:]FUNCtion?
Returned value:
CURRent|RESistance|VOLTage|POWer|SHORt
INPut:SHORt
This command indicates whether the short simulation is enabled.
Command syntax:
[SOURce:]INPut:SHORt <bool>
Parameter:
0|1|OFF|ON
Reset value:
0
Query Syntax:
[SOURce:]INPut:SHORt?
Returned value:
0|1
INPut:SHORt:FUNCtion
This command is used to enable or disable the short function.
Command syntax:
[SOURce:]INPut:SHORt:FUNCtion[:STATe] <bool>
Parameter:
O|1|OFF|ON
Reset value:
0
Query Syntax:
[SOURce:]INPut:SHORt:FUNCtion[:STATe]?