Status Commands
Copyright © Itech Electronic Co., Ltd. 50
Command syntax:
STATus:QUEStionable:ENABle <NR1>
Parameter:
065535
Power-on value:
Refer to *PSC command
Example:
STATus:QUEStionable:ENABle 16
Query syntax:
STATus:QUEStionable:ENABle?
Returned value:
<NR1>
Related command:
*PSC
Bit 0 Frequency questionable
Bit 1/2 Voltage under range
Bit 3 Voltage Over Questionable
Bit 4 Current Peak Over
Bit 5 Current Rms Over
Bit 6 Power Over
Bit 7 temperature
Bit 8 Load Fail
STATus:OPERation?
This query returns the value of the Operation Event register. After this
command is executed, the value of the Operation Event register will be cleared.
Query syntax:
STATus:OPERation[:EVENt]?