Quick Start
Copyright © Itech Electronic Co., Ltd. 18
there are 4 slot locations and each slot location has 2 channels, thus there are
8 channels in total and the channel number ranges from right to left in
sequence. if each slot has one channel, then the channel number from right to
left should be:1
th
channel,3
th
channel,5
th
channel….For module with dual
channels, the channel number should be:1th and 2th channels,3th and 4
th
channels,5
th
and 6
th
channels….IT8703 extended mainframe can be
understood in the same way.
The technical parameters of each module such as voltage, current and power
are different. Refer to Chapter5 Specifications for more details. The menu
functions of module IT8731/IT8732/IT8732B/IT8733/IT8733B/IT8731P/
IT8732P/IT8732BP/IT8733P/IT8733BP/IT8722/IT8723/IT8722B/IT8722P/IT87
23P/IT8722BP are similar. The difference between the 16 load modules is: the
input terminals of the IT8731/IT8732/IT8732B/IT8733/IT8733B/IT8722/
IT8723/IT8722B are on the rear panel of the instrument; the input terminals of
the IT8731P/IT8732P/IT8732BP/IT8733P/IT8733BP/IT8722P/IT8723P/
IT8722BP are available on the front and rear panels of the instrument. The
main functions are described as follows:
Module Features
Working functions: constant current(CC),constant resistance(CR),constant
voltage(CV),constant power(CW).
Enable you to set the rising slope and falling slope of current in dynamic
mode, dynamic functions has one mode: CC.
Dynamic mode: up to 25KHZ.
Voltage measuring resolution:0.1mV, Current measuring resolution
0.01mA(10 uA), measuring speed could reach 50KHZ.
With remote sense function.
Short-circuit function.
Storage capacity:101 sets, used to save customer’s setting parameters.
List mode: enable you to edit a list file in CC mode. Number of list steps:
2-84, each step time: 0.000020~3600s.You can save seven list files.
Auto test function, up to 10 test files or 100 test items.
2.3 Front Pannel Introduction
There’re two parts in front panel, which are main panel and module panel.
Refer to figure 2-1. Main panel and module panel keys’ function will be
introduced below.
Figure 2-1 IT8700 front panel (take example of IT8702P)

Table of Contents

Other manuals for ITech IT8702

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8702 and is the answer not in the manual?

ITech IT8702 Specifications

General IconGeneral
BrandITech
ModelIT8702
CategoryTest Equipment
LanguageEnglish

Related product manuals