Technical information
6 720 643 409 (2010/03)
23
7.3.3 E6 - E17
Unit E6 E7 E9 E11 E14 E17
Mode fluid/water
Heating output (B0/W35)
1)
1) According to EN 14511
kW
5,5 7,2 8,8 10,3 14,8 16,4
Heating output (B0/W45)
1)
kW 5,1 6,6 8,2 9,9 14,1 15,5
COP (B0/W35)
1)
4,1 4,2 4,2 4,4 4,3 4,0
COP (B0/W45)
1)
3,2 3,3 3,3 3,5 3,4 3,1
Heat transfer fluid
Nominal flow l/s 0,30 0,38 0,46 0,57 0,78 0,90
Permit external pressure drop kPa 49 45 44 80 74 71
Max. pressure bar 4
Contents (internal) l 6
Operating temperature °C –5... +20
Connection mm Ø28 Ø35
Compressor
Type Mitsubishi Scroll
Weight refrigerant R407c kg 1,6 1,6 1,8 2,4 2,3 2,3
Max. pressure bar 31
Heating system
Nominal flow l/s 0,18 0,23 0,29 0,34 0,47 0,54
Min. flow temperature °C 20
Max. flow temperature °C 65
Max. permitted operating
pressure
bar
1,5
Hot water content l 7
Connection mm Ø22 Ø28
Values for electrical connection
Electrical supply 400V 3N~50Hz
Fuse, slow; with electric add.
heat 3kW/6kW
A
16 16 16/20 16/20
Fuse, slow; with electric add.
heat 4.5 kW/9 kW
A
20/25 25/32
Nominal power consumption
compressor (B0/W35)
kW
1,33 1,64 1,99 2,22 3,15 3,73
Max. current with soft starter
2)
(accessories)
2) No soft starter in C6
A
< 30
Enclosure class IP X1
General
Permitted ambient temperature °C +10... +35
Sound pressure level
3)
3) According to EN ISO 11203
dBA
35 38 40 36 39 35
Dimensions (height x depth x
width)
mm
600 x 645 x 1520
Weight kg 146 152 155 170 190 195
Tab. 13 Technical information