9.9 Installing soft starter (accessory)
9.9.1 C6 - C11
Fig. 23 Soft starter C6-C11
Fig. 24
1. Unscrew the screws and twist the mounting rail 90°
degrees. Screw the mounting rail into place in the
existing holes.
2. Replace the contactor with the soft starter. Connect
the cables to the soft starter as they were previously
connected to the contactor.
Fig. 25 Soft starter installed
DANGER: Risk of electric shock!
B Switch off the main power supply before
starting work on the electrical part.
CAUTION: Never grasp a circuit board
without wearing a ground-connected
bracelet (Æ Chapter 3.10).
6 720 641 855-17.1I
6 720 641 855-23.1I
2
1
6 720 641 855-24.1I