25
Use the main menu
HMC300 – 6 720 813 192 (2014/10)
5.6 Set holiday program
Menu: Holiday
If you are going away for some time, or taking some time off for
a few days, you can set the holiday program. If the heat pump is
set to heating mode according to the settings for summer/
winter mode you use the holiday function. With the holiday
program the heating is set very low according to the time
program for "Saturdays", or to no heating at all.
You may decide to switch off the heating of hot water
completely during the holiday. The default settings guarantee
energy efficient and safe operation during your holiday. The
display shows to which date the holiday program is active
during the holiday period.
Fig. 4 Initial menu during the holiday period.
The settings and use of the holiday program do not change the
other time programs. When the holiday program has been
completed the control unit works with the set time programs
again. The holiday program is automatically deleted once it has
finished.
A detailed description of how to set the holiday program is
given in table 27 from page 26.
Menu: Holiday 1, Holiday 2, Holiday 3, Holiday 4 and Holiday
5
Whatever settings are used for the holiday
program, the cooling mode is not used during
the holiday.
NOTICE: Damage to the system.
▶ If you are going to be away for a long time
you should only change the settings in the
menu option Holiday.
▶ After a long period away the operating
pressure should be checked with pressure
gauge for the heating system and where
necessary solar panel system.
▶ The solar heating system should not be
switched off, even if you are away for a
long time.
6 720 811 136-31.1O
Menu options Description
Holiday
period
Set when your absence during the holiday
period starts and ends. The holiday program
starts at 00:00 on the set start date. The
holiday program continues to 24:00 on the
set date.
Selection
heat. circ./
DHW
The holiday program does not affect the
parts of the system marked here.
Only the heating/cooling circuits that are
actually installed in the system can be
selected.
Heating Control of room temperature for selected
heating circuits during the holiday period:
• With the setting As Saturday the house
heating in selected heating circuits
works every day according to the active
time program for Saturdays (holiday at
home).
• Optional Constant temperature can be
set to apply during the entire holiday for
selected heating circuits.
• With the setting Off the house heating is
completely deactivated for selected
heating circuits.
• With the setting Setback the house
heating works in selected heating
circuits in the mode set by the installer
(Reduced mode, Outside temperature
threshold, Room temperature
threshold from page 36).
DHW Hot water settings during the holiday period.
• If the setting is Off no hot water will be
produced during the entire holiday
period.
• If Off + therm. disinfection on is set the
heating of hot water is deactivated, but
thermal disinfection is carried out as
usual once a week, or once a day.
If you spend your holiday at home you must
ensure that the hot water is not marked in
the option Selection heat. circ./DHW so
that you have hot water.
Delete Delete all settings for selected holiday
program
Table 26 Settings for holiday programs