Settings
6 720 645 172 (2010/07) en
27
4.15 Read out
4.16 Quick log-out
Read out/Setting HP
Read out
I/O-status Digital inputs E2x
B Read status of the inputs. Displayed as 0 (Off) or 1 (On).
Digital outputs E2x
B Read status of the outputs. Displayed as 0 (Off) or 1 (On).
Analogue inputs E2x
B Read temperatures for the inputs.
Analogue outputs E2x
B Read opening degree/speed in % for the outputs.
Temperatures Internal sensors E2x
B Read off temperatures for sensor T6, T8, T9, T10, T11.
External sensors E2x
B Read temperatures for sensor E11.T1, E10.T2, T3. The set point for E11.T1 and stop
temperature for T3, valve and valve operation mode are also shown.
Operating times Total E2x
B Read the total number of starts and hours for Compressor, Hot water, Winter operation,
Additional heat.
Additional heat is displayed in E21.
Short time E2x
B Read the number of starts and hours for Compressor, Hot water, Winter operation,
Additional heatfor the time after reset.
Additional heat is displayed in E21.
Alarm settings E2x
B Indicate Yesif short run time will be monitored for Heatingand/or Hot water.
Information alarm Short oper. time in heating modeand/or Short oper. time in hot water
modecan now perform (Æ Chapter 5.6.44, 5.6.45, page 35).
Logging Heating, Additional heat, Hot water, etc E2x
B Set a number of hours back in time and see the status/temperatures etc at that point in time.
The values are stored each whole hour and 168 hours (=1 week) are stored.
B Use and to scroll between the different windows.
Additional heat is displayed in E21.
Alarm history Alarm history E2x
B Read all alarms and information messages, the latest is shown first.
B Use and to browse to the required alarm.
The alarm history contains the most recent 20 messages.
Program version Program version E2x
B Read the current program version for the control unit.
Tab. 46 Reading
Setting Factory Range HP
Quick log-out
Quick log-out
Current level:
No
Display
No, Yes E2x
B Indicate Yes to log out and return to the initial menu.
Tab. 47 Quick log-out