RS T4F Diesel Generator
|
G220RS 21
The optional 3-Way Fuel Valve allows the generator
to be connected to feed and return to a remote
bulk tank.
The selection lever dictates if the engine will feed
from either the base tank or bulk tank. This selection
lever should be fully engaged in the chosen position.
Please consult the manual for details of maximum
distances and acceptable elevation of bulk fuel tanks.
A
B
K
J
H
E
G
F
C
D
Fuel connections (where fitted)
A External tank
B Base tank
C Forward line (Fuel tank
suction to 3-Way fuel valve)
D Return line (3-Way fuel valve
outlet to fuel tank)
E 3-Way fuel valve
F Forward line (3-Way fuel
valve to lift pump inlet)
G Return line (Engine return
to 3-Way fuel valve)
H Direction lever
Fig 12