5.2.2 Motor Plug 3 Phase
Wago 3 Pole Plug
LINAX® / ELAX®
3 Phase
Servo motor
3 Phase
DC Motor
1
U (white)
U
DC +
2
V (brown)
V
DC -
3
W (green)
W
5.2.3 Logic and Power Supply
Wago 4 Pole Plug
1
0, GND
Adapter logic
2
24V DC
3
0, GND
Adapter power
4
12-75V DC
The typical POWER supply is 24V DC. For the stronger
LINAX® F40 / F60 axes with high masses (>2kg) or
high dynamics (>1.5m/s) a POWER supply of 48V or
72V DC is applicable. The current consumption per
axis can be up to 8A and 18A peak per axis.
Depending on mass in motion, profile and power
supply voltage.
For a fuse protection of the power supply it must be
considered that a short peak current of 8A can be
reached for the rotating field adjustment.
For a detailed calculation of the required power
supply in your application, please contact our support
https://www.jennyscience.ch/en/contact/support.
Important: The 0 volt connection of the logic supply
(pin 1) and the 0 volt connection of the power supply
(pin 3) have to be connected to the ground/chassis
star point of the switch cabinet.
Note:
In case of emission sensitivity it is recommended to
twist the supply cable for logic and power.