Jetson
www.JetsonHVAC.com
20
Digit 37 Water Side Pressure
0 = 150 psi
A = 300 psi
Digit 38 Water Strainer(s)
0 = None
A = Chilled Water Flow Wye Strainer Factory provided, field installed wye strainer can be
placed in a horizontal or vertical pipeline as long as the screen is in a downward position. Straining
is accomplished via a 20-mesh lined straining element.
B = Chilled Water Wye Strainer with Installation Kit - Wye strainer installation kits provide
piping transitions need to easily attach the wye strainer to the chiller.
C = Condenser Water Flow Wye Strainer Factory provided, field installed wye strainer can be
placed in a horizontal or vertical pipeline as long as the screen is in a downward position. Straining
is accomplished via a 20-mesh lined straining element.
D = Condenser Water Wye Strainer with Installation Kit - Wye strainer installation kits provide
the piping transitions needed to easily attach the wye strainer to the chiller.
E = Chilled and Condenser Water Nominal Flow Wye Strainer
F = Chilled and Condenser Water Wye Strainer with Installation Kit
Digit 39 Water Accessories
0 = Chilled Water Flow Switch - An evaporator flow-proving device is required for all FWCD
Series chiller applications. A paddle style liquid flow switch is available with a NEMA Type 4X
enclosure for field-installation.
A = Condenser Water Flow Switch - A paddle style liquid flow switch is available with a NEMA
Type 4X enclosure for field-installation.
B = Analog Water Temperature Gauge - Temperature gauges are factory installed on water lines
to indicate water temperature.
C = Analog Water Pressure Gauge - Pressure gauges are factory installed on water lines to
indicate pressure drop across heat exchangers.
D = Chilled Water Flow Switch + Condenser Water Flow Switch
E = Chilled Water Flow Switch + Analog Water Temperature Gauge
F = Chilled Water Flow Switch + Analog Water Pressure Gauge
G = Chilled Water Flow Switch + Condenser Water Flow Switch + Analog Water
Temperature Gauge
H = Chilled Water Flow Switch + Condenser Water Flow Switch + Analog Water Pressure
Gauge
J = Chilled Water Flow Switch + Analog Water Temperature Gauge + Analog Water
Pressure Gauge
K = Chilled Water Flow Switch + Condenser Water Flow Switch + Analog Water
Temperature Gauge + Analog Water Pressure Gauge