11. CP Parameter List
Cp.xx Name Units Default Value Description
00 Password - - -
01 Inverter Status - Read Only -
02 Control Setting - - 0 = ASCL, 1 = Open Loop V/Hz, 2 = Closed Loop
03 DASM Rated Power kW 18.5 kW Motor Nameplate
04 DASM Rated Speed rpm 1170 rpm Motor Nameplate
05 DASM Rated Current A 35.0 A Motor Nameplate
06 DASM Rated Frequency Hz 60.0 Hz Motor Nameplate
07 DASM Rated Voltage V 460 V Motor Nameplate
08
DASM Rated Cos(phi)
[Power Factor]
- 0.90 Motor Nameplate
09 Load Motor Data - - 2 = Load Motor Data
10 Motor Learn - - 0 = Off, 7 = Motor Learn
11
Electronic Motor Overload
Protection
- - 0 = On (single motors; EOH2 active),
6 = Off (parallel motors)
12
Electronic Motor Overload
Protection Current
A 35 A Motor Nameplate
13 High Speed rpm 1170 rpm X2A.10
14 Low Speed rpm 292 rpm X2A.11
15 Inspection Speed rpm 0.0 rpm X2A.10 + X2A.11
16 Acceleration Time secs 10.0 sec Time required to accelerate to command speed
17 Deceleration Time secs 10.0 sec Time required to decelerate to command speed
18 Open Loop V/Hz Frequency Hz 60 Hz Motor Nameplate
19
Low Speed Torque Boost
(Open Loop, V/Hz Only)
% 10.0% -
20
Encoder Pulses Per
Revolution (PPR)
inc/rev 1024 inc/rev Encoder Pulse Number
21
Encoder Rotation Channel - 0 = Not Inverted
0 = Not Inverted, 1 = AB Swapped
16 = Inverted Rotation, 17 = AB Swap & Inverted Rot.
22 KP Speed - 1500 -
23 KI Speed - 200 -
24 KI Offset - 50 -
25 Input Status coded Read Only See Section 3 for values
26 Output Status coded Read Only See Section 3 for values
27 Command Speed rpm Read Only -
28 Actual Motor Speed rpm Read Only -
29 Output Frequency Hz Read Only -
30 Output Current A Read Only -
31 Peak Output Current A Read Only -
32 DC Bus Voltage V Read Only -
33 Output Voltage V Read Only -
34 Modulation Grade % Read Only -
35 Download Datecode - Read Only -
36 Last Error - Read Only -

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5
CategoryDC Drives
LanguageEnglish

Related product manuals