Page #102 background imageLoading...
Page #102 background image
MAINTENANCE 6-19
6. Check temperature of electrolyte, if it
reaches 40°C (105°F), lower the
charging rate. When temperature is too
high, reduce charging rate and charge
for a proportionately longer period.
7. If the tractor is stored after original
charge, periodically recharge as
shown below :
A battery is fully charged when the
cells are all gassing freely and the
specific gravity ceases to rise for
three consecutive readings taken at
hour intervals. Specific gravity shall
then be adjusted to showed in Table
1.
8. Check electrolyte level two hours af-
ter chargingis finished and correct it.
< Table 3 >
about 5 hours
10
30
Period of storage
from manufacture
(months)
Fresh charging
(times)
0 ~ 6
6 ~ 12
over 12
5. Batteries are preferably charged by
current showed in Table 2. Keep vent
plugs removed during charging.
< Table 2 >
TYPE
Volt (V)
Number of
plate per
cell
Capacity
at
20H.R
(A.H.)
Volume of
Electrolyte
(
)
Normal
Charging
Rate(A)
N70ZL 75D26L
PT80 -
34FR
12
15
70
4.7
7
12
13
65
4.2
7
12
-
100
5.4
5 ~ 10

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kioti DK35 and is the answer not in the manual?

Kioti DK35 Specifications

General IconGeneral
Engine TypeDiesel
Engine Power35 hp
TypeCompact utility tractor
PTO HP28.5 hp
Drive4WD
PTO Power28.5 hp
3-Point HitchCategory I
Engine3-cylinder
Hydraulic Remotes2

Related product manuals