10
4.1(e) Push the choke knob in to the OPEN position as the engine warms up.
Fig.10
4.2 High altitude operation
At high altitude, the standard carburetor air-fuel mixture will be excessively rich
Performance will decrease, and fuel consumption will increase.
High altitude performance can be improved by installing a smaller diameter main fuel jet in the
carburetor. If you always operate the generator at altitudes higher than 5000 feet or 1500 meters
above sea level, have your authorized dealer install a high altitude main jet.
Even with suitable carburetor jetting, engine horsepower will decrease approximately 3.5% for each
1000 feet or 305 meter increase in altitude. The effect of altitude on the horsepower will be greater
than this if no carburetor modification is made.
Operation of the generator at an altitude lower than the carburetor is
jetted for may result in reduced performance, overheating, and
serious engine damage caused by an excessively lean air/fuel
mixture. Be sure to have any modification reversed at lower altitudes.
4.3 Ambient Temperature
Generator output generally derates 1% for every 10° F (5.5° C) above 85° F (29° C). The normal
operating range of the generator is -20° to 113° F (-29° to 45° C).
Do not operate the generator when the ambient temperature is below
-20° F (-29°)
Do not operate the generator when the ambient temperature is above
113° F (45° C)
Choke knob

Other manuals for Kipor IG3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kipor IG3000 and is the answer not in the manual?

Kipor IG3000 Specifications

General IconGeneral
BrandKipor
ModelIG3000
CategoryPortable Generator
LanguageEnglish

Related product manuals