TP-6811 7/1654 Section 4 Cooling System
4.2 Clean Radiator Fins and
Inspect Hoses
To prevent generator set from shutting down or
becoming damaged due to overheating, keep the
cooling air inlets clean and unobstructed at all times.
Inspect the exterior of the radiator for obstructions;
remove all dirt and foreign material with a soft brush or
cloth (to avoid damaging radiator fins). Check all hoses
and connections for leaks and replace any hoses that
are cracked, frayed, or feel spongy. When coolant level
checks are made, check the condition of the radiator cap
rubber seal; replace if cracked or deteriorating. Remove
dirt and other debris from the radiator cap and filler neck.
4.3 Engine Thermostat
See Figure 4-1 for the location of the engine thermostat.
The thermostat rating is shown in Figure 4-2. Refer to
the engine service manual for thermostat and water
pump service information.
1. Thermostat
1
TP-6812
Figure 4-1 Thermostat Location on the Engine
(48RCL shown)
Item Rating
Thermostat
71_C (160_F)
Figure 4-2 Thermostat Rating
9
10
1
GM83070
1. Radiator
2. Radiator fill/pressure cap
3. Upper radiator hose
4. Engine compartment
temperature sensor
5. Engine compartment fan
6. Lower radiator hose
7. Coolant overflow bottle
8. Coolant overflow tube
9. Low coolant level sensor
10. Radiator fans
4
7
5
2 3
6
8
Figure 4-3 Cooling System Components

Table of Contents

Other manuals for Kohler 38RCLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 38RCLA and is the answer not in the manual?

Kohler 38RCLA Specifications

General IconGeneral
BrandKohler
Model38RCLA
CategoryInverter
LanguageEnglish

Related product manuals