6 Commissioning/Start-up/Shutdown
33 of 68
Calio
1157.821/04-EN
6.1.3 Start-up
DANGER
Non-compliance with the permissible pressure and temperature limits if the pump
is operated with the suction and discharge lines closed.
Hot fluids escaping!
Never operate the pump with the shut-off elements in the suction line and/or
discharge line closed.
Only start up the pump set against a slightly or completely open discharge-side
shut-off element.
DANGER
Excessive temperatures due to insufficient lubrication of the plain bearings
Damage to the pump set!
Never operate the pump set without liquid fill.
Prime the pump as per operating instructions.
Always operate the pump within the permissible operating range.
WARNING
Hot surfaces (Pump and piping take on the temperature of the fluid handled.)
Risk of burns!
Do not touch hot surfaces.
CAUTION
Abnormal noises, vibrations, temperatures or leakage
Damage to the pump!
Switch off the pump (set) immediately.
Eliminate the causes before returning the pump set to service.
ü The system piping has been cleaned.
ü Pump, suction line and inlet tank (if fitted) have been vented and primed with
the fluid to be handled.
ü The priming lines and venting lines have been closed.
1. Fully open the shut-off element in the suction head line/suction lift line.
2. Close or slightly open the shut-off element in the discharge line.
3. Start up the motor.