18 SERVICE WORK ON THE ENGINE
142
E00917-10
Main work
–
Remove protection cap
1
of the diagnostics connector.
E00819-11
–
Put throttle grip
2
into full throttle position and secure.
E00918-10
–
Plug in wake-up connector
3
for priming the oil pump to the
diagnostics connector
4
.
The combination instrument lighting is activated.
Info
The connector is included as part of the motorcycle's
separate enclosure.
– Wait for at least five seconds.
– Release the fixing means from the throttle grip.
The oil pump is timed.
Info
The oil pump is actuated at various speeds.
The procedure is clearly audible.
– Wait until you can no longer hear the oil pump working.
– Disconnect the wake-up connector from the diagnostics con-
nector.
M01515-10
–
Check whether air bubbles are visible in the hose
5
.
» If air bubbles are visible:
– Repeat the entire procedure until air bubbles are no
longer visible.
– Mount protection cap on the diagnostics connector.
Finishing work
– Mount the seat. ( p. 80)