19HANDLING THE CIRCUIT BREAKER
ENGLISH
HANDLING THE CIRCUIT BREAKER
MOKUJIYOU
C Single phase (3 terminals - Dual voltage type)
Panel control is designed to have the two A.C. circuit
breaker.
Turn ON the same voltage number circuit breaker as
using the A.C. voltage.
[3 terminals type]
A Do not add the A.C. load directly, using the circuit
breaker.
A The simultaneous generation of 220V power source
and 110V (or 127V) power source is possible but the
total load should not exceed the following rated
output.
BHandling the Circuit Breaker (Protector)
(Australian model)
Each of the receptacles is provided with an over-current
circuit protector.
If any of the circuit protectors is activated and the current
flow is interrupted, stop the engine and check the load.
C Resetting the Circuit Protector
1. If an over-current occurs, the center knob of the circuit
protector pops up.
2. Press down the knob to reset the circuit protector.
To avoid personal injury:
A Before resetting the circuit protector,
be sure to stop the engine. An
attempt to reset it with the engine
running is very dangerous.
(1) Circuit breaker
(1) Circuit breaker (Main)
(2) Circuit protector (Receptacle)
(3) Receptacles