LaserRange-Master X2
15
* measuring distance up to 10 m with strongly reflective target
surface and at room temperature. The measurement deviation
may increase by +/-0.2 mm/m for greater distances and under
unfavourable measuring conditions such as strong sunlight or
weakly reflective target surfaces.
Technical Data (Subject to technical changes without notice)
Inside measurement range 0,5 m - 25 m
Precision (typical) ± 3 mm / 10 m*
Laser class 2 < 1mW
Laser wavelength 650 nm
Power supply 2 x AAA 1.5 Volt batteries
Dimensions 110 x 43 x 28 mm
Weight (incl. batteries) 110 g
Automatic switch-off
30 sec LCD lighting /
45 sec laser / 3 min device
Operating temperature 0°C – 40°C
Storage temperature -20°C – 70°C
Article number 080.944A
Error codes:
301:
302:
303:
304:
305:
306:
307:
308:
Target is outside measuring range.
Target is too dark or too much ambient light. Use
a reflecting material as target for the measurement.
Measured value cannot be shown by LC display.
Set measured values to zero with button (4.).
Pythagoras parameter error
Replace the battery.
Temperature is too low: < 0 °C
Temperature is too high: > 40 °C
Too much ambient light.
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info
GB