Operation Messages
Sprinter 50 - 1.0.0en
8. Operation Messages
E115 Temperature Sensor
Error !
Cover the objective telescope with a hand and switch ON the instrument.
Hardware communication failed.
E116 Adjustment Error ! Carry out the adjustment with guided steps, make sure instrument is level
and staff is truly vertical in normal position. Collimation is out of correction
range.
E119 Staff Blocked Not enough barcode length for measurement.
E120 Image sensor Error! Contact services.
E121 Adjustment Inverse
Staff Not Allowed!
Check the staff orientation and staff setting.
No. Error message Counter measure / causes
Operation message Counter measure / remark
Abort Measurement! Current measuring process is terminated.
Wait! File System Clean Up! Cleaning up of temporary files/system files.
Shut Down! System is switching OFF.
Sand Clock Icon Please wait! System task is in progress.