Harmony
®
II Residential Zone Control System − Component Selection
(Heat Pump Systems)
STOP
ROUND
ZONE DAMPERS
RECTANGULAR
ZONE DAMPERS
NO
NO
DAMPER
TRANSFORMER
up to 5 Dampers
(87344) 45VA
ECONOMIZER
DAMPERS
EMD14-65 or
EMD14M-65
ECONOMIZER
DAMPERS
WIRING HARNESS
120 volts (14H57)
ELECTRONIC AIR
CLEANER
EAC17-14 (75H10)
EAC17-14SQ (75H11)
EAC17-20 (75H12)
ZONE
THERMOSTAT
(One Required
For Each
Additional Zone)
ZONE 1
MASTER
THERMOSTAT
DISCHARGE AIR
SENSOR PROBE
(16J98)
START
MULTI-POSITION
TWO ZONES
TWO, THREE
OR FOUR
ZONES
SINGLE SPEED
OUTDOOR UNIT
HP26
HP27
HP29
10HPB
12HPB
MULTI-POSITION
BLOWER COIL
CB31MV SERIES
HEAT PUMP
SYSTEM
PRESSURE
SWITCH
(21J18)
CONTROL
CENTER
(16J95)
TWO-SPEED
OUTDOOR UNIT
HP21
CONTROL
PANEL
(16J96)
Catalog
Description No.
*2 Htg.-1 Clg. 7 Day Programmable 91H72. . . . . . . . . . . . . . . . . .
3 Htg.-2 Clg. 7 Day Programmable 18H13. . . . . . . . . . . . . . . . . . .
3 Htg.-2 Clg. Digital Setpoint 13K97. . . . . . . . . . . . . . . . . . . . . . . .
2 Htg.-1 Clg. 5-1-1 Day Programmable 27H30. . . . . . . . . . . . . . .
**2 Htg.-1 Clg. Electro−mechanical w/ Subbase 51H40. . . . . . . .
*Recommended programmable master thermostat or zone thermostat.
**Recommended electro−mechanical zone thermostat.
ROUND DAMPERS
Catalog
Description No.
6 in. (152 mm) dia. 77G99. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 in. (203 mm) dia. 78G00. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 in. (254 mm) dia. 78G01. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 in. (305 mm) dia. 78G02. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 in. (356 mm) dia. 78G03. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RECTANGULAR DAMPERS
Catalog
Description No.
10 in. x 8 in. (254 x 203 mm) 78G04. . . . . . . . . . . . . . . . . . . . . . . .
12 in. x 8 in. (305 x 203 mm) 78G05. . . . . . . . . . . . . . . . . . . . . . . .
14 in. x 8 in. (356 x 203 mm) 78G06. . . . . . . . . . . . . . . . . . . . . . . .
16 in. x 8 in. (406 x 203 mm) 78G07. . . . . . . . . . . . . . . . . . . . . . . .
18 in. x 8 in. (457 x 203 mm) 78G08. . . . . . . . . . . . . . . . . . . . . . . .
20 in. x 8 in. (508 x 203 mm) 78G09. . . . . . . . . . . . . . . . . . . . . . . .
RECOMMENDED THERMOSTATS
(For a complete selection of alternate thermostats, see
Thermostats Bulletin in Accessories section.)
ZONE DAMPERS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox Harmony II Zone Control System and is the answer not in the manual?

Lennox Harmony II Zone Control System Specifications

General IconGeneral
BrandLennox
ModelHarmony II Zone Control System
CategoryControl Systems
LanguageEnglish

Related product manuals