Specications
General
Data
Model No. EL16XP1-018 EL16XP1-024EL16XP1-030EL16XP1-036
Nominal Tonnage 1.522.53
1
Sound Rating Number (dBA) 71 72 72 72
Connections
(sweat)
Liquid line (o.d.) - in. 3/83/8 3/83/8
Suction line (o.d.) - in. 3/43/4 3/47/8
Refrigerant
2
R-410A charge furnished 6 lbs. 6 oz.6 lbs. 11 oz.7 lbs. 10 oz.8 lbs. 7 oz.
Outdoor
Coil
Net face area - sq. ft. Outer coil 24.5 18.7 18.7 22.2
Inner coil - - -18.018.021.5
Tube diameter - in. 5/16 5/16 5/16 5/16
No. of rows 12
22
Fins per inch 22 22 22 22
Outdoor
Fan
Diameter - in. 22 22 22 26
No. of blades 33
33
Motor hp 1/6 1/6 1/6 1/3
Cfm 2670 2575 2575 3700
Rpm 867866 866820
Watts 160163 163200
Shipping Data - lbs. 1 pkg. 213211 211214
ELECTRICAL DATA
Line voltage data - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph
3
Maximum overcurrent protection (amps) 20 20 25 35
4
Minimum circuit ampacity 12.2 13.6 16.4 20.9
Compressor Rated load amps 910.112.314.7
Locked rotor amps 48 52 63 75
Power factor 0.98 0.98 0.96 0.99
Outdoor Fan Motor Full load amps 1.01.0 1.02.6
Locked rotor amps 1.91.9 1.9- - -
CONTROLS
iComfort
®
E30 Smart Wi-Fi Thermostat 15S63 ••
••
Remote Outdoor Temperature Sensor X2658 ••
••
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Compressor Crankcase Heater 93M04 ••
Factory
Compressor Hard Start Kit LG 88M91 ••
••
Compressor Low Ambient Cut-Off 45F08 ••
••
Freezestat 3/8 in. tubing 93G35 ••
••
5/8 in. tubing 50A93 ••
••
Indoor Blower Off Delay Relay 58M81 ••
••
Loss of Charge Switch Kit 84M23 ••
••
5
Low Ambient Kit 54M89 ••
••
Mild Weather Kit 11B97 ••
••
Monitor Kit - Service Light 76F53 ••
••
Outdoor Thermostat Kit Thermostat 10Z23 ••
••
Mounting Box 31461 ••
••
Refrigerant
Line Sets
L15-41-20
L15-41-30
L15-41-40
L15-41-50
••
6
Snow Guard 35-1/2 x 31 in. (Canada Only) X8780 ••
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Sound Rating Number rated in accordance with test conditions included in AHRI Standard 270.
2
additional refrigerant charge required.
3
HACR type breaker or fuse.
4
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
5
Crankcase Heater and Freezestat are recommended with Low Ambient Kit.
6
Add 11-1/2 inches (292 mm) to unit height.

Other manuals for Lennox HFC-410A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox HFC-410A Series and is the answer not in the manual?

Lennox HFC-410A Series Specifications

General IconGeneral
BrandLennox
ModelHFC-410A Series
CategoryHeat Pump
LanguageEnglish

Related product manuals