11
1.7. MPAMulti-ZoneSpecicationsOutdoorUnits(1.5-2.5Ton)
Nominal Size - Tons 1.5 2.5
Outdoor Unit Model No. MPA018S4M MPA030S4M
Number of Zones 2 Up to 3
1
AHRI Ratings SystemType Ducted Non-Ducted Ducted Non-Ducted
Cooling-Btuh 17,000 18,000 27,000 25,000
HighTemperatureHeating-Btuh 18,000 18,500 32,000 32,000
LowTemperatureHeating-Btuh 10,900 11,000 20,000 20,000
SEER 18.00 21.00 16.50 22.00
EER 12.50 12.50 9.50 12.50
HSPF(RegionIV) 8.5 9.6 8.8 9.6
AHRIReferenceNumber 8129621 8129607 8129624 8129613
Energy Star Yes Yes No Yes
Ambient Temperature Range - °F Cooling 5 - 122 5 - 122
Heating –13 - 76 –13 - 76
Sound Data (dBA) Cooling 57 59
Heating 62 62
Refrigerant Chargefurnished(R-410A) 4lbs.4oz. 6lbs.3oz.
Maximumlinelengthwithfurnishedcharge(perzone)-ft. 25 25
Additionalchargerequiredperft.-oz. 0.161 0.161
Compressor No.andType Twin-Rotary Twin-Rotary
Refrigerantoiltype ESTEROILVG74 ESTEROILVG74
Refrigerantoilcharge-oz. 16.9 27.7
Connections - in. Liquid+Gaspipe(are) (2)1/4+(2)3/8 (3)1/4+(3)3/8
Maximumlengthforallrooms-ft. 98 148
Maximumlengthforoneindoorunit-ft. 66 82
Maximumheight
differencebetween
indoor unit and outdoor
unit
OutdoorunitABOVE
indoor unit - ft.
33 33
OutdoorunitBELOW
indoor unit - ft.
49 49
Maximumdifferenceinlevelbetweenindoorunits-ft. 33 33
Outdoor
Fan
(No.)Diameter-in. (1) - 18 (1) - 22
Totalairvolume-cfm 1470 2060
rpm 750 850
Outdoor Coil Numberofrows 2 1.6
Finsperinch 14 15
Fintype Hydrophilicaluminium
Tubeoutsidediameter-in. 3/8 3/8
Tubetype Riedcoppertubing
Net face area - ft.
2
4.9 6.42
Design Pressure PSIG 550/340 550/340
Shipping Data Net/Shippingweight(lbs.) 106 / 115 144/155
ELECTRICAL DATA
Electrical Characteristics - 60 Hz - 1 Phase 208/230V 208/230V
2
MaximumOvercurrentProtection(amps) 20 25
3
Minimum circuit ampacity 18 20
CompressorRatedloadamps 10 12
Outdoor Fan Motor Ratedloadamps 0.74 0.90
Output-W 50 120
NOTE-PerAHRI,thecertiedratingsforsystemsarevalidforallcombinationsofindoorunitswiththespecicoutdoorunitslistedaboveandintheAHRIDirectoryof
CertiedEquipment.Pleasevisithttp://www.ahridirectory.orgforfurtherdetailsandlatestupdates.
1
RatingsareAHRIcertiedtoAHRIStandard210/240-2008;
•CoolingRatings-80°Fdrybulb/67°Fwetbulbenteringindoorcoilairand95°Fdrybulb/75°Fwetbulboutdoorairtemperature.
•HighTemperatureHeatingRatings-70°Fdrybulb/60°Fwetbulbenteringindoorcoilairand47°Fdrybulb/43°Fwetbulboutdoorairtemperature.
•LowTemperatureHeatingRatings-70°Fdrybulb/60°Fwetbulbenteringindoorcoilairand17°Fdrybulb/15°Fwetbulboutdoorairtemperature.
NOTE-Extremesofoperatingrangeareplusandminus10%oflinevoltage.
2
HACRtypecircuitbreakerorfuse.
3
RefertoNationalorCanadianElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements.
NOTE-Adaptorsarefurnishedforthegaspipeconnections:
018 - (2) 3/8 x 1/2 in.
030 - (3) 3/8 x 1/2 in.