15
1.11. MLAMulti-ZoneSpecicationsOutdoorUnits(1.5-3Ton)
Nominal Size - Tons 1.5 2.5 3
Outdoor Unit Model No. MLA018S4M MLA030S4M MLA036S4M
Number of Zones 2 Up to 3 Up to 4
1
AHRI Ratings SystemType Ducted Non-Ducted Ducted Non-Ducted Ducted Non-Ducted
Cooling-Btuh 18,000 19,000 27,000 28,000 35,000 36,000
HighTemperatureHeating-Btuh 18,000 20,000 27,000 28,000 35,000 36,000
LowTemperatureHeating-Btuh 11,800 12,600 16,600 18,000 24,400 23,200
SEER 16.8 21.5 17.6 22 17 21.5
EER 11.3 12.5 10.8 13 10.8 13.5
HSPF(RegionIV) 8.6 9.8 9.1 10.4 9.2 10.5
AHRIReferenceNumber 9920052 9920051 9920053 9920054 9920056 9920055
Energy Star No Yes No Yes No Yes
Ambient Temperature Range - °F Cooling –22 - 122 –22 - 122 –22 - 122
Heating –22 - 86 –22 - 86 –22 - 86
Sound Data (dBA) Cooling 63.4 62.3 64
Heating 63.4 62.3 64
Refrigerant Chargefurnished(R-410A) 6lbs.3oz. 6lbs.10oz. 10lbs.2oz.
Maximumlinelengthwithfurnishedcharge(perzone)-ft. 25 25 25
Additionalchargerequiredperft.-oz. 0.161 0.161 0.32
Compressor No.andType Rotary Rotary Twin-Rotary
Refrigerantoiltype POEVG74 POEVG74 ESTEROILVG74
Refrigerantoilcharge-oz. 22.7 33.8 47.3
Connections - in. Liquid+Gaspipe(are) (2)1/4+(2)3/8 (3)1/4+(3)3/8 (3)1/4liq.+(3)3/8gas
(1)1/4liq.+(1)1/2gas
Maximumlengthforallrooms-ft. 148 197 246
Maximumlengthforoneindoorunit-ft. 82 98 98
Maximumheight
differencebetween
indoor unit and outdoor
unit
OutdoorunitABOVE
indoor unit - ft.
33 33 33
OutdoorunitBELOW
indoor unit - ft.
49 49 49
Maximumdifferenceinlevelbetweenindoorunits-ft. 33 33 33
Outdoor
Fan
(No.)Diameter-in. 20 20 (2) 22
Totalairvolume-cfm 2130 2355 (2)4470
rpm 150/200/250/300/400/500/6
00/750/900/10,000
150/200/250/300/400/500/6
00/750/900/10,000
150/200/250/300/400/500/6
00/700/800/870
Outdoor Coil Numberofrows 2 2 2
Finsperinch 17 19 18
Fintype Hydrophilicaluminium
Tubeoutsidediameter-in. 3/8 3/8 3/8
Tubetype Riedcoppertubing
Net face area - ft.2 8.24 8.16 13.40
Design Pressure PSIG 550/340 550/340 550/340
Shipping Data Net/Shippingweight(lbs.) 150 / 161 157 / 168 224/255
ELECTRICAL DATA
Electrical Characteristics - 60 Hz - 1 Phase 208/230V 208/230V 208/230V
2
MaximumOvercurrentProtection(amps) 25 40 50
3
Minimum circuit ampacity 19 27 35
CompressorRatedloadamps 20 22 21
Outdoor Fan Motor Ratedloadamps 0.9 1.3 (2) 0.39
Output-W 120 120 (2) 85
NOTE-PerAHRI,thecertiedratingsforsystemsarevalidforallcombinationsofindoorunitswiththespecicoutdoorunitslistedaboveandintheAHRIDirectoryof
CertiedEquipment.Pleasevisithttp://www.ahridirectory.orgforfurtherdetailsandlatestupdates.
1
RatingsareAHRIcertiedtoAHRIStandard1230-2010withAddendum2;
•CoolingRatings-80°Fdrybulb/67°Fwetbulbenteringindoorcoilairand95°Fdrybulb/75°Fwetbulboutdoorairtemperature.
•HighTemperatureHeatingRatings-70°Fdrybulb/60°Fwetbulbenteringindoorcoilairand47°Fdrybulb/43°Fwetbulboutdoorairtemperature.
•LowTemperatureHeatingRatings-70°Fdrybulb/60°Fwetbulbenteringindoorcoilairand17°Fdrybulb/15°Fwetbulboutdoorairtemperature.
NOTE-Extremesofoperatingrangeareplusandminus10%oflinevoltage.
2
HACRtypecircuitbreakerorfuse.
3
RefertoNationalorCanadianElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements.
NOTE-Adaptorsarefurnishedforthegaspipeconnections:
018 - (2) 3/8 x 1/2 in.
030 - (3) 3/8 x 1/2 in.