16. Outdoor Unit Condensate Piping
Condensate formed during the heating and defrost processes must be drained from heat pump units. Drain holes are
provided in the base of the units to ensure proper drainage. Heat pumps must be raised when installed on a concrete pad or
the ground to allow drainage to occur. If the heat pump unit is installed on wall mounting brackets, insert the provided drain
connector into one of the 1 inch (25 mm) drain holes and attached a eld-provided insulated drain hose to the connector.
Use eld-provided rubber plugs to cover any unused drain holes.
Drain
Connector
Chassis
Condensate Drain
(location varies per model)
Note: Used if the unit is hanging on the wall and
needs to have the water moved away.
Figure 32. Condensate Drainage Requirement