506601−01
Air Handler / Coil Match ups and Targeted Subcooling Values
Listed below are the targeted subcooling and charging values for approved indoor unit air handler / coil match ups. This
information is also listed on the unit charging sticker located on the access panel.
* Indicates amount of charge required in additional to charge shown on unit nameplate. Remember to consider line set
length differences.
Table 4  XP21−024
Model Number
Target SC
Add
Charge*
Heat
(+5ºF)
Cool
(+1º)
lb. oz.
CB(X)27UH−024 15 4 0 0
CB(X)27UH−030 22 7 1 10
CBX32M−036 and CBX32MV−036 22 7 1 10
CBX32M−030 and CBX32MV−24/30 15 4 0 0
CBX40UHV−024 22 7 1 10
CBX40UHV−030 22 7 1 10
CBX40UHV−036 22 7 1 10
CH23−51 18 4 0 10
CH33−31 18 4 0 10
CH33−42 18 4 0 10
CR33−48 32 4 0 0
CR33−50/60C 14 7 1 10
CX34−31 27 4 0 10
CX34−34/48B 22 5 1 3
CX34−38 25 6 1 7
Table 5  XP21−036
Model Number
Target SC
Add
Charge*
Heat
(+5ºF)
Cool
(+1º)
lb. oz.
CB(X)27UH−036 17 5 0 0
CB(X)27UH−042 12 5 1 10
CBX32M−036 and CBX32MV−036 17 5 0 0
CBX32M−048 and CBX32MV−048 12 5 1 10
CBX40UHV−036 17 5 0 0
CBX40UHV−042 12 5 1 10
CBX40UHV−048 12 5 1 10
CH23−51 19 7 0 0
CH33−43 11 5 0 7
CH33−44/48B 11 5 0 7
CH33−48C 11 5 0 7
CH33−50/60C 12 7 1 6
CR33−48 32 4 0 7
CR33−50/60C 11 4 1 8
CX34−38 15 5 0 7
CX34−43 11 5 0 7
CX34−44/48B 19 4 0 10
CX34−49 10 10 1 10
CX34−50/60C 11 5 0 7
Table 6  XP21−048
Model Number
Target SC
Add
Charge*
Heat
(+5ºF)
Cool
(+1º)
lb. oz.
CB(X)27UH−048 24 4 1 0
CB(X)27UH−060 14 4 1 6
CBX32M−048 and CBX32MV−048 24 4 1 0
CBX32M−060 and CBX32MV−060 21 4 1 14
CBX32MV−068 14 4 1 0
CBX40UHV−048 24 4 1 0
CBX40UHV−060 21 4 1 14
CH23−68 14 4 1 6
CH33−49C 21 4 1 14
CH33−50/60C 21 4 1 14
CH33−62D 20 4 1 7
CR33−50/60 32 4 0 0
CR33−60D 32 4 0 0
CX34−49 21 5 0 10
CX34−62C 11 4 1 5
CX34−62D 11 4 1 5
Table 7  XP21−060
Model Number
Target SC
Add
Charge*
Heat
(+5ºF)
Cool
(+1º)
lb. oz.
CB(X)27UH−060 7 6 0 10
CBX32M−060 and CBX32MV−060 10 4 0 0
CBX32MV−068 9 4 0 10
CBX40UHV−060 10 4 0 0
CH23−68 10 4 0 10
CH33−49C 7 5 0 0
CH33−50/60C 7 5 0 0
CH33−62D 9 4 0 7
CR33−50/60 22 5 0 4
CR33−60D 22 5 0 4
CX34−49 10 5 0 4
CX34−62C 7 5 0 0
CX34−62D 7 5 0 0

Other manuals for Lennox XP21 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lennox XP21 Series and is the answer not in the manual?

Lennox XP21 Series Specifications

General IconGeneral
BrandLennox
ModelXP21 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals