Product description
Connections and interfaces
16
Lenze · Decentralised frequency inverter 8400 motec (CANopen option) · EDS84DMOTCAN EN 4.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
By default, the CANopen connectors are already pre-assembled and wired with the terminal
strip X3.
The CANopen connections and further connections (e.g. digital inputs) can be freely designed at
the positions A1 ... A4 and B1 ... B4..
For the connections, 5-pin M12 connectors or - alternatively - cable glands (cable cross-section
max. 1.0 mm
2
, AWG 18) can be used.
The M12 connectors, cable glands and prefabricated system cables can be obtained from
various manufacturers.
Wire the M12 plugs or cable glands used with the corresponding contacts of the terminal strips
X3, X4 and X61.