Lenze · Decentralised frequency inverter 8400 motec (CANopen option) · EDS84DMOTCAN EN 4.0 - 02/2019 91
Implemented CANopen objects
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
I-1016 - Consumer heartbeat time
Monitoring time for the nodes to be monitored via heartbeat.
Heartbeat protocol
( 66)
The parameterised time is rounded down to an integer multiple of 5 ms and must have a greater
value than the heartbeat producer time of the node to be monitored.
[13-4] Data telegram assignment
I-1017 - Producer heartbeat time
Time interval for the transmission of the heartbeat telegram to the consumer(s).
Heartbeat protocol
( 66)
The parameterised time is rounded down to an integer multiple of 5 ms.
The heartbeat telegram is transmitted automatically as soon as a time > 0 ms is set. In this case,
the node guarding monitoring function is deactivated.
This object relates to code C00381
.
Note!
The identifier can only be changed in the "emergency object invalid" status (bit 31 = 1).
Index:
I-1016
Name:
Consumer heartbeat time
Subindex Default setting Setting range (min. value | unit | max. value) Access Data type
0: Highest subindex supported 1 - (read access only) ro U16
1 ... n: Consumer heartbeat time 0 0 65535 rw U16
Subindex Meaning Lenze code
0 Number of nodes to be monitored
1 ... n Node ID and heartbeat time of the node to be monitored Node ID:
C00385/x
Heartbeat time:
C00386/x
8th byte 7th byte 6th byte 5th byte
Data 4 Data 3 Data 2 Data 1
Bit 31 ... bit 24 Bit 23 ... bit 16 Bit 15 ... bit 0
0
Reserved
Node ID Heartbeat time
in [ms]
Index:
I-1017
Name:
Producer heartbeat time
Subindex Default setting Setting range (min. value | unit | max. value) Access Data type
0: Producer heartbeat time 0 0 ms 65535 rw U16

Table of Contents

Other manuals for Lenze 8400 motec Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8400 motec Series and is the answer not in the manual?

Lenze 8400 motec Series Specifications

General IconGeneral
BrandLenze
Model8400 motec Series
CategoryDC Drives
LanguageEnglish

Related product manuals