6
2. Technical data
2.1. General data
Enclosure
Steel sheet housing, IP20 to DIN 40050
Noise immunity:
Severity 4 to IEC 801-4
Influence of installation height on
rated current:
1000 m: 100% rated current
2000 m: 95% rated current
3000 m: 90% rated current
4000 m: 85% rated current
Ambient temperature
0 °C...+45 °C during operation
-25 °C...+55 °C during storage
-25 °C...+70 °C during transport
Permissible humidity
relative humidity 80%, no condensation
Permissible pollution
Pollution strength 2 to VDE 0110, part 2.
Do not expose units to corrosive or explosive gases.
2.2. Unit-specific data
2.2.1. Rated data of supply modules
Supply module type 9212_E 9215_E 9217_E
Order no. 33.9212_E 33.9215_E 33.9217_E
Mains voltage
[V] 3 x 480; 50 - 60 Hz
permissible range 3 x 330...528
±
0%;
DC-bus voltage
(at rated current)
[V] 1.35 x V
mains
Mains current
[A
eff
]
62040
Permanent power
1)
(at V
mains
= 3 x 480 V)
[kW] 4.9 16.5 33
Peak power
(t=5 s)
[kW] 12 37 60
Permanent brake power (with int.
brake resistor)
[W] 250
Permanent brake power (with
appropriate ext. brake resistor)
[kW] 4.9 16.5 33
Peak brake power
with int. or ext. brake resistor
[kW] 19.4 51.1 66.1
min. permissible resistance for int.
or ext. brake resistor
[Ω]
29 11 8.5
Power loss (without brake resistor)
[W] 110 110 110
Weight
[kg] 9.0 10.5 11.0
1)
With low mains voltages, the permissible permanent power is reduced to P
zul
= P
n
V
mains
/ 480 V