Page #26 background image
Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Diagnostics
3
26
EDKVF93−03 EN 2.0
3.1.8 Diagnostics
In the "Diagnostic" menu the two submenus "Actual info" and "History" contain all codes
for
ƒ monitoring the drive
ƒ fault/error diagnosis
In the operating level, more status messages are displayed. If several status messages are
active, the message with the highest priority is displayed.
Priority Display Meaning
1 GLOBAL DRIVE INIT Initialisation or communication error between
keypad and controller
2 XXX − TRIP Active TRIP (contents of C0168/1)
3 XXX − MESSAGE Active message (contents of C0168/1)
4
Special device states:
Switch−on inhibit
5
Source for controller inhibit (the value of C0004 is displayed simultaneously):
STP1
9300 servo: Terminal X5/28
ECSxS/P/M/A: Terminal X6/SI1
STP3 Operating module or LECOM A/B/LI
STP4 INTERBUS or PROFIBUS−DP
STP5
9300 servo, ECSxA/E: System bus (CAN)
ECSxS/P/M: MotionBus (CAN)
STP6 C0040
6
Source for quick stop (QSP):
QSP−term−Ext The MCTRL−QSP input of the MCTRL function block is on HIGH signal.
QSP−C0135 Operating module or LECOM A/B/LI
QSP−AIF INTERBUS or PROFIBUS−DP
QSP−CAN
9300 servo, ECSxA: System bus (CAN)
ECSxS/P/M: MotionBus (CAN)
7 XXX − WARNING Active warning (contents of C0168/1)
8 xxxx Value below C0004
efesotomasyon.com - Lenze

Other manuals for Lenze 9300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 9300 Series and is the answer not in the manual?

Lenze 9300 Series Specifications

General IconGeneral
BrandLenze
Model9300 Series
CategoryController
LanguageEnglish

Related product manuals