Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06 93
13 Error messages
13.2 Possible causes and remedies
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.2 Possible causes and remedies
This chapter lists all EtherCAT error messages in the numerical order of the error numbers. Possible
causes and remedies as well as responses to the error messages are described in detail.
EtherCAT: Connection to 9400 lost [0x00c83100]
EtherCAT: Internal supply voltage too low [0x00c85114]
EtherCAT: Memory: No access [0x00c85531]
EtherCAT: Memory: Error while reading [0x00c85532]
EtherCAT: Memory: Error while writing [0x00c85533]
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
The MXI communication to the Servo Drive 9400 is
interrupted.
Servo Drive 9400 is switched off.
The communication module is not connected
correctly at the MXI slot of the Servo Drive 9400.
Switch on Servo Drive 9400.
Plug in the communication module correctly at the
MXI slot of the Servo Drive 9400.
Send communication module and Servo Drive 9400
with error description to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Voltage loss of the standard device Check voltage supply.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Access to memory was not possible. Send communication module together with a
description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameter could not be read. Send communication module together with a
description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause Remedy
Parameter could not be written. Send communication module together with a
description of the fault to Lenze.

Table of Contents

Other manuals for Lenze 9400 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 9400 Series and is the answer not in the manual?

Lenze 9400 Series Specifications

General IconGeneral
BrandLenze
Model9400 Series
CategoryServo Drives
LanguageEnglish

Related product manuals