Parameter setting
7-11
BA9300SU EN 2.1
7.2.3 Save parameter set
You have to save the modified parameters, if you do not want to loose them after mains
disconnection.
• You can establish up to four parameter sets, e.g. if you process different materials on a
machine or if this is required by different operating states (setup mode, ”stand-by”).
• If you need only one parameter set, save the modifications permanently under parameter set
1, since the controller automatically loads parameter set 1 after mains connection.
How to proceed
1. Change from the menus to the code level using the arrow keys.
”Code” is displayed.
2. With
?
or
+
select C0003.
3. Change to the parameter level using PRG.
”Para” is displayed.
4. With
?
or
+
set parameter to 1 (possible even when the drive is running).
Note: If the parameter set is to be saved under another number, select 2, 3, or 4 instead of 1.
5. Press SHIFT + PRG.
”OK” is displayed for approx. 1 s.
Now your settings are saved permanently under parameter set 1 (or 2, 3, 4).