Parameter setting
7-11
BA9300SU EN 2.1
7.2.3 Save parameter set
You have to save the modified parameters, if you do not want to loose them after mains
disconnection.
You can establish up to four parameter sets, e.g. if you process different materials on a
machine or if this is required by different operating states (setup mode, stand-by).
If you need only one parameter set, save the modifications permanently under parameter set
1, since the controller automatically loads parameter set 1 after mains connection.
How to proceed
1. Change from the menus to the code level using the arrow keys.
Code is displayed.
2. With
?
or
+
select C0003.
3. Change to the parameter level using PRG.
Para is displayed.
4. With
?
or
+
set parameter to 1 (possible even when the drive is running).
Note: If the parameter set is to be saved under another number, select 2, 3, or 4 instead of 1.
5. Press SHIFT + PRG.
OK is displayed for approx. 1 s.
Now your settings are saved permanently under parameter set 1 (or 2, 3, 4).