Maintenance
Important notes
7
41
Lenze ¯ MA 12.0012 ¯ 4.0
7 Maintenance
7.1 Important notes
Note!
¯ Gearboxes below 200 Nm are lubricated for life.
¯ The mechanical power transmission system is maintenance−free.
¯ Before commissioning remove transport locking devices and keep them for later
transports.
¯ Take safety measures prior to any operation:
Disconnect the machine from the mains, ensure standstill of the drive system
and avoid any machine movement.
That the ambient temperature match the data on the nameplate.
7.2 Maintenance intervals
Stop!
For drive systems: Also observe the maintenance intervals for the other
drive components!
Dust deposits prevent heat to be emitted and cause a high housing temperature. The
gearboxes/geared motors must be purified of dirt and dust at regular intervals.
¯ In the case of gearboxes that are not lubricated for life, the lubricant must be
replaced at regular intervals.
The type of lubricant is indicated on the nameplate. Replace the lubricant only
with the same type of lubricant.
The lubricant change depends on the lubricant temperature, see Fig. 11.
1. Measure the lubricant temperature at the drain plug,
2. Add 10 °C,
3. Read the changing interval from the diagram.