Technical data
Rated data
4
EDKRBM001 DE/EN/FR 6.1
37
l
H1_Daten−Abm_BF3_BL
Rated data
Electrical data
R
B
P
d
Q
B
U
max
[W]
[W] [kWs] [V
DC
]
ERBM052R200W 52
200 30.0
800
ERBM082R150W
82
150 22.5
ERBM082R200W 200 30.0
ERBM100R150W 100 150 22.5
ERBM200R100W 200 100 15.0
ERBM240R200W 240 200 30.0
ERBM370R150W 370 150 22.5
ERBM470R050W
470
50 7.5
ERBM470R100W 100 15.0
R
B
Resistance
P
d
Permanent power
Q
B
Heat quantity
U
max
Max. operating voltage
Temperatures
T
nom
T
TK
T
max
[°C]
On the surface 150 250 500
On the clearance
edge
*)
90 100 120
T
nom
Maximum temperature for rated data
T
TK
Temperature at which the thermal contact is activated
T
max
Maximum temperature in the case of improper use
*) Measured for air as the ambient medium (small coefficient of
thermal conductivity); if materials which heat up are located
at the clearance edge (greater coefficient of thermal
conductivity), the temperature continues to rise.