Page #33 background imageLoading...
Page #33 background image
Before measuring resistance, be sure to turn power off, and do voltage discharge.
(When discharging, contact the metal plug of power cord with earth line.)
During diagnostic test, E5 error occur.
Turn the dryer’s power off, then measure resistance.
After activating the *diagnostic test, press
START/PAUSE button 4 times.
Is AD value displayed higher than 10 ?
•Replace the
DC pump
Normal condition
YES
NO
* diagnostic test : go to page 23
Test 8
Motor Assembly, DC, Pump
Caution
Trouble Symptom
Measurement Condition
32

Questions and Answers:

Question and Answer IconNeed help?