REFRIGERATOR MICOM
ICE PLUS
The ICE PLUS setting runs the compressor continuously for 3 hours with the
freezer fan on the HIGH (2,700 rpm) setting. This intensifies the cooling speed
and the amount of ice made. For the remainder of the 24 hour cycle (21 hours),
the freezer will maintain the lowest temperature. After the 21-hour time has
passed, the freezer defaults to its previous setting. The fan will turn off while any
door is opened.
If a defrost cycle begins during the first 90 minutes of Ice Plus, Ice Plus will
complete its cycle after the defrost is completed. If defrost begins more than 90
minutes into the Ice Plus cycle, Ice Plus will run for two hours after the defrost
has ended.
The freezer fan normally runs at 2,400 rpm. The high speed (2,700 rpm) is used
when ICE PLUS is operated, at initial power up, and when the freezer is
overloaded. When the ICE PLUS option is functioning, the LED is on.
In the event of a power failure, ICE PLUS is cancelled and the product returns to
its default settings.
LAMP AUTO-OFF
To avoid excess heat and the associated damage, the interior lamps will turn off
automatically when the door is left open for more than 7 minutes.
LFX21960ST/LFX25960xx Page 46 of 75 TRAINING MANUAL