1
Press the button.
2
Press the button.
3
Set the volume of each air flow ( Lo→Med→Hi) by
using the button. Press the button to select
the air flow.
(The value of E.S.P could be adjusted from 1 to 255.)
(The figure on the left shows when the strong wind’s
ESP value has been set to 212.)
4
If you press the button one more time, the
E.S.P value will be set and the setting mode will be
unset.
E.S.P function is setting the volume of each air flow. It is for the convenience of installation. It is recommended
that you should not use this function while using the wireless remote controller.
* Slo and Po setting is not available for some products.
* Because the EPS value is already appropriately set when manufactured from the factory, it is recommended that
you do not change the ESP value.
Installer Setting - ESP Function
If you set ESP incorrectly, the air conditioner may malfunction.
This setting must be carried out by a certificated-technician.