MT3010-E MT4010-E MT3010-E-BT MT4010-E-BT
30A 40A 30A 40A
12V/24V automatical recognization
before boost or equalization charging stage
14~14.8/28~29.6V @25(default: 14.5/29V)
14~15.0/28~30V@25(default: 14.8/29.6V)(Liquid, AGM)
13~14.5/26~39V @25(default: 13.7/27.4V)
10.8~11.8V/21.6~23.6V, SOC1~5(default: 11.2/22.4V)
11.4~12.8V/22.8~25.6Vdefault: 12.0/24.0V)
15.8/31.3V
35V
-4.17mV/K per cell (Boost, Equalization),
-3.33mV/K per cell (Float)
10.0~32.0V(Lithium, default: 14.4V)
9.2~31.8V(Lithium, default: 14.0V)
9.0~30.0V(Lithium, default: 10.6V)
9.6~31.0V(Lithium, default: 12.0V)
Gel, AGM, Liquid, Lithiumdefault: Gel)
100V(-20), 90V(25)
390/780W 520/1040W 390/780W 520/1040W
8.0/16.0V
*2
Battery Voltage + 1.0V)~Voc*0.9
30A
Always on, Street Lamp, Evening, Manual
>99.9%
98.0%
189 * 255 * 63mm
1.3Kg 1.5Kg 1.3Kg 1.5Kg
8mA(12V); 12mA(24V)
RS485(RJ11 interface) BLE, RS485(RJ11 interface)
Cyber-BT, IoT IoT
Common Negative
6AWG(16mm²)
-20 ~ +55
-25 ~ +80
0 ~ 100%RH
IP32
4000m
Battery
Parame-
ters
Panel
Parame-
ters
Load
System
Parame-
ters
Item
Max Charging Current
System Voltage
MPPT Charging Voltage
Boost Voltage
Equalization Voltage
Float Voltage
Low Volt. Disconnect
Reconnect Voltage
Overcharge Protect
Max volt on Bat. terminal
Temp. Compensation
Charging target voltage
Charging recovery voltage
Low voltage disconnect
Low voltage reconnect
Battery Type
*1
Max volt on PV terminal
Max input power
Day/Night threshold
MPPT tracking range
Output Current
Load mode
Max tracking efficiency
Max charge conversion
Dimensions
Weight
Self consumption
Communication
Optional
Grounding
Power terminals
Ambient temperature
Storage temperature
Ambient humidity
Protection degree
Max Altitude
8, Technical Data
*1.This value represents the maximum voltage of the solar panel at the minimum operating ambient
temperature.
*2.Voc means the open circuit voltage of the solar panel.
*3.Around oblique line value separately on behalf of 12V/24V system's value.