Specification of compressed air
General
For compressed air quality observe the ISO 8573-1:2010. Compressed air
must be free of solid particles and oil (acc. to the specification).
Requirements
The starting air must fulfil at least the following quality requirements accord-
ing to ISO 8573-1:2010.
Purity regarding solid particles
Particle size > 40µm
Quality class 6
max. concentration < 5 mg/m
3
Purity regarding moisture
Residual water content
Quality class 7
< 0.5 g/m
3
Purity regarding oil Quality class X
Additional requirements are:
â–ª The air must not contain organic or inorganic silicon compounds.
â–ª The layout of the starting air system must ensure that no corrosion may
occur.
â–ª The starting air system and the starting air receiver must be equipped
with condensate drain devices.
â–ª By means of devices provided in the starting air system and via mainte-
nance of the system components, it must be ensured that any hazard-
ous formation of an explosive compressed air/lube oil mixture is preven-
ted in a safe manner.
Please note that control air will be used for the activation of some safety
functions on the engine – therefore, the compressed air quality in this system
is very important.
Control air must meet at least the following quality requirements according to
ISO 8573-1:2010.
â–ª Purity regarding solid particles
Quality class 5
â–ª Purity regarding moisture
Quality class 4
â–ª Purity regarding oil
Quality class 3
For catalysts
The following specifications are valid unless otherwise defined by any other
relevant sources:
Compressed air for soot blowing must meet at least the following quality
requirements according to ISO 8573-1:2010.
â–ª Purity regarding solid particles
Quality class 3
â–ª Purity regarding moisture
Quality class 4
â–ª Purity regarding oil
Quality class 2
Compressed air for atomisation of the reducing agent must fulfil at least the
following quality requirements according to ISO 8573-1:2010.
Compressed air quality of
starting air system
Compressed air quality in the
control air system
Compressed air quality for
soot blowing
Compressed air quality for
reducing agent atomisation
2016-10-27 - de
Quality guidelines (conventional and Common Rail
engines)
Quality guidelines (conventional and Common Rail engines)
General
MAN Diesel & Turbo
010.000.023-21
D010.000.023-21-0001 EN 1 (2)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Man L16/24 and is the answer not in the manual?

Man L16/24 Specifications

General IconGeneral
BrandMan
ModelL16/24
CategoryPortable Generator
LanguageEnglish

Related product manuals