Part Number 000015432 4/18 73
FLOAT SWITCH
FUNCTION
The float switch prevents the ice machine from running
when the water level is below the control setpoint.
The float switch must be closed (float in up position)
before the ice machine will start, and must remained
closed throughout the freeze cycle.
SPECIFICATIONS
A mechanical liquid level sensor, that magnetically
operates a reed switch.
CHECK PROCEDURE
NOTE: The water float switch is connected to the water
reservoir cover. The reservoir cover must be in place and
water must be present in the reservoir to close the switch.
Verify water is supplied to the float valve, the water
inlet screen is clean, and the float and float arm are free
moving.
1. Disconnect power to the ice machine.
2. Disconnect the float switch from the control board
and connect an ohm meter to the switch wires.
3. Verify the switch is in the up position (reservoir full of
water), then check continuity.
Step 3 Check for Continuity
Reading Result
Closed The switch is working properly
Open Replace the switch
4. Remove cover from reservoir by lifting straight up.
Verify the switch opens as the float drops.