–189–
Contamination Cleanup Chart
Symptoms/Findings
Required Cleanup
Procedure
No symptoms or suspicion
of contamination
Normal
evacuation/recharging
procedure
Moisture/Air
Contamination symptoms
Refrigeration system
open to atmosphere for
longer than 15 minutes
Refrigeration test kit
and/or acid oil test
shows contamination
No burnout deposits in
open compressor lines
Mild contamination
cleanup procedure
Mild Compressor Burnout
symptoms
Oil appears clean but
smells acrid
Refrigeration test kit or
acid oil test shows
harmful acid content
No burnout deposits in
open compressor lines
Severe contamination
cleanup procedure
Severe Compressor
Burnout symptoms
Oil is discolored, acidic,
and smells acrid
Burnout deposits found
in the compressor, lines,
and other components
Severe contamination
cleanup procedure